Purpose

Duchenne muscular dystrophy (DMD) is an X-linked disorder that causes muscle wasting, cardiopulmonary failure, and premature death. Heart failure is a leading cause of death in DMD, but substantial knowledge gaps exist regarding predisposing risk factors. In the general population, hyperglycemia, insulin resistance, and decreased heart rate variability (HRV; reflecting autonomic dysfunction) are associated with cardiomyopathy (CM). It is unclear whether these factors are associated with DMD-CM. Closing this knowledge gap may lead to novel screening and therapeutic strategies to delay progression of DMD-CM, now the leading cause of death in patients with DMD. Despite risk factors for hyperglycemia, including the use of glucocorticoids (GCs), sarcopenia, obesity, and reduced ambulation, little is known regarding glucose abnormalities in DMD. Some of these same risk factors, along with the distance needed to travel for specialty care, present significant barriers to research participation and clinical care for individuals with DMD. Remote wearable technology may improve research participation in this vulnerable population. Therefore, this study will leverage remote wearable technologies to overcome these barriers and define the relationship between dysglycemia and DMD-CM. The goal of this remote study is to evaluate rates of hyperglycemia in individuals with DMD compared to control participants using continuous glucose monitors, and to determine the relationship between hyperglycemia and heart rate variability. Participants will utilize continuous glucose monitors, cardiac monitors, and activity monitors to evaluate glucose levels, heart rate, activity, and sleep.

Condition

Eligibility

Eligible Ages
Over 10 Years
Eligible Genders
Male
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • Male - Age ≥10years - Clinical phenotype of DMD confirmed with muscle biopsy or genotype. - Informed consent for individuals ≥18 years - Parent/guardian informed consent and child assent for individuals < 18 years CASE, DMD

Exclusion Criteria

  • Refusal to participate. - Diagnosis of diabetes prior to the study and/or taking insulin or other anti-diabetic drug therapy in < 4 weeks prior to treatment - Use of a pacemaker, Implantable cardioverter-defibrillator (ICD), or other implanted device - Unable to comply with study procedures, in the opinion of the investigator. CONTROL inclusion criteria: - Male - Age ≥10years - Informed consent for individuals ≥18 years - Parent/guardian informed consent and child assent for individuals < 18 years - BMI matched by Centers for Disease Control and Prevention (CDC) category (underweight, normal, overweight, obese) to cases. - Self-reported race/ethnicity matched to cases. - No known evidence of diabetes, impaired fasting glucose, or impaired glucose tolerance: - For individuals (all ≥10 years) of age with obesity, we anticipate that they will have hemoglobin A1c (HbA1c) screening based on American Academy of Pediatrics (AAP) recommendations. - Participants will be included if they have a normal HbA1c (< 5.7%) or if they have an elevated HbA1c (5.7-6.4%) with no evidence of impaired fasting glucose or impaired glucose tolerance on clinically obtained oral glucose tolerance tests (OGTT) (e.g., fasting glucose <100mg/dL and 2-hour glucose <140mg/dL). CONTROL, exclusion criteria: - Refusal to participate. - Diagnosis of diabetes prior to the study and/or taking insulin or other anti-diabetic drug therapy in < 4 weeks prior to treatment - Use of a pacemaker, Implantable cardioverter-defibrillator (ICD), or other implanted device - Unable to comply with study procedures, in the opinion of the investigator. - Diagnosis of DMD or Becker muscular dystrophy

Study Design

Phase
Study Type
Observational
Observational Model
Case-Control
Time Perspective
Cross-Sectional

Arm Groups

ArmDescriptionAssigned Intervention
Case - DMD 40 male individuals with DMD
  • Device: wearable technology
    Three wearable devices
    Other names:
    • Continuous glucose monitor (CGM): The Dexcom G6 Pro Continuous Glucose Monitoring System (Dexcom G6 Pro System)
    • Holter Monitor: Body Guardian Mini Remote Monitoring System
    • Physical activity and sleep monitor: ActiGraph GT9X accelerometers
Controls 40 matched controls (gender, age ± 1 year, BMI category, self-reported race/ethnicity).
  • Device: wearable technology
    Three wearable devices
    Other names:
    • Continuous glucose monitor (CGM): The Dexcom G6 Pro Continuous Glucose Monitoring System (Dexcom G6 Pro System)
    • Holter Monitor: Body Guardian Mini Remote Monitoring System
    • Physical activity and sleep monitor: ActiGraph GT9X accelerometers

Recruiting Locations

Vanderbilt University Medical Center
Nashville, Tennessee 37232
Contact:
Jaclyn Tamaroff, MD
615-875-7853
Jaclyn.tamaroff@vumc.org

More Details

Status
Recruiting
Sponsor
Vanderbilt University Medical Center

Study Contact

Jaclyn Tamaroff, MD
615-875-7853
Jaclyn.tamaroff@vumc.org

Detailed Description

This study is a critical first step in evaluating hyperglycemia in DMD and the relationship to autonomic dysfunction. Our findings will help establish screening guidelines and provide a basis for intervention studies targeting glycemia in DMD. Additionally, this study, along with other ongoing studies (Wearable Technology to Evaluate Hyperglycemia and Heart Rate Variability in Duchenne Muscular Dystrophy - longitudinal aim) will establish wearable technology as investigational tools, for potential use in future clinical trials, in individuals with DMD and neuromuscular diseases. Study Population: This study will include approximately 40 participants with DMD and 40 age/gender/BMI category, race and ethnicity matched participants without DMD. DMD is an X-linked disorder affecting approximately 1/3500-6000 males and 1/50 million females. Therefore, only males will be included in this study. Study Enrollment Period: Expected duration of the study is 6 years. Study procedures (remote or in-person): - Medical history and record review - Continuous Glucose Monitor (CGM) A CGM sensor (Dexcom Pro, Dexcom Inc, San Diego, CA) will be placed on the abdomen of each participant during the study visit or sent to the participant's home. If the CGM sensor is placed remotely, the process of CGM placement will be reviewed over a video call with study staff. Participants will wear the CGM for up to 10 days (blinded) then return it via pre-paid envelope. The CGM collects glucose data every 5 minutes. Participants will be offered an optional "skin grip" adhesive (Skin Grip, Bountiful, UT) that they have the option to place over the CGM sensor to help keep it in place. - Activity Monitoring (ActiGraph) Activity and sleep duration will be measured over 1-week using the ActiGraph accelerometers (ActiGraph, LLC, Pensacola, FL). Participants are instructed to wear the monitors on their dominant wrist for 7 days, 24 hours per day. Data is collected via ActiGraph at a rate of 40Hz and analyzed in 15-second epochs (ActiLife version 6.4 software, Pensacola, FL). For both activity and sleep parameters, the minimum valid wear time to utilize the data is 1 weekend day/night and 3 weekday days/nights with at least 6 hours of wear time per day/night. - Holter (cardiac) Monitoring An extended-wear Holter monitor (Body Guardian Mini, Preventice, Rochester, MN) will be placed by study personnel during in person visits or participants at home. Participants will wear the monitor for 7 days at the same time they are wearing the CGM and ActiGraph. HRV is automatically calculated by the software. - Diary/electronic survey Participants will be asked to complete a brief diary/survey response (approximately 5-minute survey twice daily). The REDCap survey diary will be texted to participants in the morning and evening via REDCap/Twilio. The diary will include questions related to sleep, activity, and food intake. Participants will be asked to complete the survey for the 7 days that they are wearing both the ActiGraph and the CGM.

Notice

Study information shown on this site is derived from ClinicalTrials.gov (a public registry operated by the National Institutes of Health). The listing of studies provided is not certain to be all studies for which you might be eligible. Furthermore, study eligibility requirements can be difficult to understand and may change over time, so it is wise to speak with your medical care provider and individual research study teams when making decisions related to participation.